(Continued)
NOTE: Shutdown is recommended at the end of
a workday or whenever no frying is required for a
period of several hours. The fryer MUST be
shutdown during any power outage or interruption
of gas service. To prevent damage, the fryer
MUST also be shutdown whenever there is no
shortening in the kettle.
1. Turn the thermostat knob to OFF.
2. Turn the gas control valve knob to align the
PILOT setting with the valve mark.
3. Open the pilot viewing/lighting port to con-
firm that only the pilot flame remains lighted.
SHUTDOWN PROCEDURE
4. Press, and turn, the gas control valve
knob to align the OFF setting with the valve
mark. Observe that the pilot flame goes out.
5. Switch the POWER switch to OFF.
NOTE: For extended periods of non-use
or when servicing the fryer, close the gas
supply line inlet valve to the fryer by turning
the gas valve handle cross-wise with the gas
line piping. Also, switch the circuit breaker