Antunes, AJ MS-250/255 Electric Steamer User Manual


 
MIRACLE STEAMER
10
P/N 1010699 Rev. B
A.J. Antunes & Co.
READY
UP DOWN PROGRAM START/STOP
POWER
1500
Figure 6. Control Programming Sequence
READY
UP DOWN PROGRAM START/STOP
POWER
15
READY
UP DOWN PROGRAM START/STOP
POWER
00
READY
UP DOWN PROGRAM START/STOP
POWER
sho
READY
UP DOWN PROGRAM START/STOP
POWER
00
READY
UP DOWN PROGRAM START/STOP
POWER
20
READY
UP DOWN PROGRAM START/STOP
POWER
H20
READY
UP DOWN PROGRAM START/STOP
POWER
0 70
NOTE: Use the UP or DOWN Arrow Buttons to change the minute or second time interval.
6. Depress the program button once and use the
UP or DOWN arrow buttons to change the SHO
(Shot Interval Time) in seconds (Item E, Figure
6).
NOTE: 20 seconds is recommended.
7. Depress the program button again and use the
UP or DOWN arrow buttons to change the SHO
(Shot Interval Time) in minutes (Item F, Figure 6).
NOTE: 20 seconds is recommended.
8. Depress the program button again and H
2
O will
be displayed (G, Figure 6).
9. To change the H
2
O (Steam Shot) factory settings
(default), depress the program button again to
display the default setting (Item H, Figure 6). Use
the UP or DOWN arrow buttons to increase or
decrease the time.
A. Default Setting
B. Total Cycle Minutes
C. Total Cycle Seconds
D. SHO Cycle
E. SHO Time in Seconds
F. SHO Time in Minutes
G. H
2
O Cycle
H. H
2
O Default Setting
NOTE: Recommended settings are:
MS-250/255 - [0_40] or 0.40 sec (120 VAC)
MS-250/255 - [0_70] or 0.70 sec (208-240 VAC)
MS-150/155/355 - [1_00] or 1.00 sec (208-240 VAC)
10. Press the Start/Stop button to store the changes,
exit the PROGRAM Mode and initiate the cooking
cycle.
NOTE: The Start/Stop button may be pressed at any
time during programming to store the changes and exit
the PROGRAM Mode.
NOTE: If no change is made within 10 seconds at any
time during the programming process, all changes
made up to that point are stored in memory and the
control reverts to the OPERATION Mode.