Antunes, AJ MS-250/255 Electric Steamer User Manual


 
MIRACLE STEAMER
16
P/N 1010699 Rev. B
A.J. Antunes & Co.
Steam from generator is
reduced compared to former
operation.
Unit becomes flooded or
always steaming. Power
ON, solenoid makes a chat-
tering noise.
or
Unit floods overnight. Power
OFF.
Water leaking in the
electrical housing.
Restrictor tube or generator tubes are
clogged.
Flooding condition.
Insufficient preheat.
Filters require cleaning.
Control board setpoint temperature
too low.
Heavy deposit buildup on the genera-
tor.
Incorrect water pressure.
Solenoid valve inoperable or particles
in the valve.
Control board is not programmed
properly.
Control board is inoperable.
Pin hole leak in the hoses.
Inlet tube or restrictor tube is loose.
Generator tube is loose or damaged.
Clean restrictor tube and/or generator
tubes.
Allow 20 minutes for excess water to evapo-
rate and generator to recover to 375°F.
Allow excess water on the generator casting
to evaporate and preheat 20 minutes before
operating. DO NOT operate steamer during
preheat cycle.
See page 14.
Surface temperature of the casting should
be between 375°- 425° F (191°- 218°C)
when the red light on the control board
turns off. If the temp is too low, contact
maintenance or AJA Authorized Service
Center.
See maintenance procedure under
Cleaning
Generator.
*(Regulated units only.) Set water pressure
to 20 psi (138 kPa).
May need to cleaned or replaced. Contact
maintenance or AJA Authorized Service
Center.
Verify programming as described in the
Programming
section.
Contact maintenance or AJA Authorized
Service Center.
Replace the hoses.
Tighten the loose fittings.
Tighten loose fittings or contact mainte-
nance or AJA Authorized Service Center.
Problem Possible Cause Corrective Action