Antunes, AJ MS-250/255 Electric Steamer User Manual


 
MIRACLE STEAMER
17
P/N 1010699 Rev. B
A.J. Antunes & Co.
Unit heats up, pump or sole-
noid valve works with the
momentary switch but will
not steam during timer
cycles.
Steam coming out around
top covers or sides.
Programming.
If Ready light does not light but the
unit steams regularly, the Ready light
is inoperable.
If the Ready light does light and the
unit does not steam, the control board
is inoperable.
*(Direct Feed Units) Quick-disconnect
not connected properly or inoperable.
Water volume adjustment is too low.
Water filter clogged.
Inoperable solenoid or solenoid dam-
age caused by connecting a hot
water supply line.
Inoperable control board.
Wingnut is loose.
Generator cover damage.
See pages 8-10.
Contact maintenance or AJA Authorized
Service Center.
Contact maintenance or AJA Authorized
Service Center.
Make sure the quick-disconnect and O-ring
are properly positioned and are not dam-
aged. Replace damaged parts.
Adjust the water volume control. See
Calibration
section of the manual.
Remove and clean filter.
Make sure unit is connected to a cold water
supply. Contact maintenance or AJA
Authorized Service Center.
Contact maintenance or AJA Authorized
Service Center.
Tighten wingnut.
Adjust or replace generator cover.
Problem Possible Cause Corrective Action