Belshaw Brothers 724CG Fryer User Manual


 
Belshaw Bros., Inc. 1750 22
nd
Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322-5425
718LCG, 724CG, and 734CG Gas Fryers MN-1141EN 9
WARNING
Do not allow the shortening to overflow the
containers. Shortening will get on the
floor, and if the shortening is not cool
enough, you may be burned.
WARNING
Thoroughly clean and dry the floor if
shortening is spilled. Shortening on the
floor can cause serious injury or loss of life.
6. Using a non-abrasive, non-metallic spatula,
scrape the sediment and any remaining
shortening into the drain valve.
WARNING
To avoid fire, serious injury, and
equipment damage, do not attempt to burn
carbon off of the heat tubes.
7. Close the drain valve.
8. If your fryer has a Belshaw Shortening
Melter (FM) connected to it, install the plug
into the reservoir nipple.
Washing
1. Pour hot water into the kettle, up to the
normal level of the shortening. Add
trisodium phosphate or another appropriate
cleaner.
CAUTION
To avoid severe damage to the kettle, never
turn on the heat unless the heat tubes are
completely covered by liquid.
2. Connect the fryer to the power source.
Move the on/off switch to ON. Set the
temperature control to 200°F/93°C. Keep
the cleaning solution at this temperature for
15-20 minutes.
3. Scrub the soiled parts while the solution is
hot. Do not use any abrasive cleaners or
scrapers.
WARNING
To avoid being burned, be very careful as
you work with hot cleaning solution. Never
put your hands in the solution. Wear
gloves and long sleeves in case any solution
splashes.
4. Move the on/off switch to OFF and
disconnect the fryer from the power source.
Allow the cleaning solution to cool to
100°F/38°C.
5. Place a large metal container under the drain
valve.
WARNING
Do not use plastic containers. If the
cleaning solution is not cool enough, the
containers will melt; possibly causing you
to be burned, and causing cleaning solution
to get on the floor.
6. Open the drain valve and allow the cleaning
solution to drain into the container.
7. Watch the container to make sure the
cleaning solution does not overflow. If the
container becomes full, close the drain
valve, put another large metal container
under the drain valve, and open the drain
valve again.