Belshaw Brothers 724CG Fryer User Manual


 
Belshaw Bros., Inc. 1750 22
nd
Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322-5425
718LCG, 724CG, and 734CG Gas Fryers MN-1141EN 13
Open Kettle Fryer Parameter Settings
Tables 1, 2 and 3 below list of the temperature controller default settings and the Belshaw Factory
settings. When installing a new controller 4 of the default setting must be changed to the Belshaw
Factory settings.
Push and hold the scroll key
for 3 seconds, this will take you to the “SEt” menu.
Push the scroll key
once to access the “LocK” parameter.
Push the Up
or down arrow keys to change “LocK” to “nonE”.
Push the scroll key
to page through the settings and the Up or down arrow keys to
change the settings listed in the Belshaw “Factory” column. (see tables 1, 2 and 3)
When finished setting parameters.
Continue pushing the scroll key
until you are back to “LocK”.
Push the Up
or down arrow keys to set “LocK” to “uSEr”.
Push the reset key
to return normal operation.
Default Settings:
In the event that parameters have been modified without recording the modifications, change each
parameter to match those listed in Tables 1, 2 and 3 listed below (controller parameter default settings).
Then adjust SP1H, PB, OUT2 and the LocK parameters as listed in Belshaw “Factory” below. Then set
SP1 to 375ºF.