Belshaw Brothers TG 50 Microwave Oven User Manual


 
Belshaw Bros., Inc. 1750 22
nd
Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322-5425
Thermoglaze 50 MN-1716EN 25
THE PUMP MOTOR WILL NOT RUN
Possible Causes What To Do
The connection of the power cord to the power
source is faulty.
Make sure the power cord is fully plugged in to a
proper power source.
The circuit breaker has been tripped. 1. Disconnect from power.
2. Open electrical enclosure.
3. Reset circuit breaker.
4. Close electrical enclosure.
THE FILL HOSE IS LEAKING
Possible Causes What To Do
Fill hose is leaking at the connection. Hose bracket needs adjusting or tightening.
Fill hose is leaking near the pump. Check for missing or damaged o-ring.