Bertazzoni PRO244GASX Range User Manual


 
15
GASCONVERSION
WARNING!
Beforecarryingoutthisoperation,disconnect
theappliancefromgasandelectricity.
Gasconversionshallbeconductedbyafactory
trainedprofessional.
Callthecustomerservicehotlinetoidentifya
factorytrainedprofessionalnearyourhome.
The gas conversion procedure for this range
includes6steps:
1. Pressureregulator
2. Surfaceburn ers
3. Mainovenburner
4. Broilerburner
5. Visualcheckspriortoclosureofovenbottom
panel
6. Adjustmentofminimumsetting
The conversion is not completed if all 6 steps
havenotbeenconcludedproperly.
Beforeperformingthegasconversion,locatethe
package containing the replacement nozzle
shipped with every range. IMPORTANT: Each
nozzlehasanumberindicatingitsflowdiameter
printedonthebody.Consultthetableonpage20
formatchingnozzlestoburners.
Save the nozzles removed from the range for
futureuse.
STEP1:PRESSUREREGULATOR
The pressure regulator supplied with the
applianceisaconvertibletypepressureregulator
for use with Natural Gas at a nominal outlet
pressureof4”w.c.orLPgasatanominaloutlet
pressure of11” w.c. andit is prearranged from
the factory to operate with one of these
gas/pressureasindicatedinthelabels
affixedon
theappliance,packageandInstructionbooklet.
Toconverttheregulatorforusewithotherliquid
propaneLPgas:
1. Unscrew by hand the upper cap of the
regulator, remove the white plastic
attachment from the cap, reverse its
directionand screwitagainfirmlyagainstthe
cap.The
whiteplasticattachmenthasarrows
indicating theposition for natural gas (NAT)
andLPgas(LP).
2. Screw by hand the metal cap in the original
positionontheregulator.