20
Adapting to different types of gas
Burner Position Injector Gas Pressure Max Rate Min Rate By-pass
diam. [mm.] Type [i.w.c.] [BTU/h] [W] [BTU/h] [W] diam. [mm]
Auxiliary Rear L
0,92
NG 4”
3750 1098
900 264 Regulated
0,56
LP (Propane) 11”
3750 1098
900 264 0,29
Semi-Rapid Front R
1,17
NG 4”
6000 1759
1500 439 Regulated
0,73
LP (Propane) 11”
6300 1845
1500 439 0,36
Rapid Rear R
1,55
NG 4”
10400 3046
2500 732 Regulated
0,98
LP (Propane) 11”
11400 3339
2500 732 0,47
Front L Inner
0,80
NG 4”
2730 799
900 264 Regulated
Dual Burner
0,50
LP (Propane) 11”
2900 849
900 264 0,29
Front L Outer
N°2x1,30
NG 4”
15000 4394
4500 1318 Regulated
N°2x0,83
LP (Propane) 11”
16400 4804
4500 1318 0,65
Oven Oven 1,60 NG 4” 11000 3223 2400 703 Regulated
downside 0,95 LP (Propane) 11” 11000 3223 2400 703 0,48
Broiler Oven 1,50 NG 4” 10000 2930 Only Max Only Max No by-pass
upside 0,90 LP (Propane) 11” 10000 2930 Only Max Only Max No by-pass