7
BEFOREINSTALLATION
This appliance shall only be installed by an
authorizedprofessional.
This appliance shall be installed in accordance
withthemanufacturer’sinstallationinstructions.
This appliance must be installed in accordance
withthenorms&standardsofthecountrywhere
it will be installed. The installation of this
appliance must conform to local
codes and
ordinances. In the abs ence of local codes,
InstallationsmustconformstoAmericanNational
Standards,NationalFuelGasCodeANSIZ223.1–
latestedition**orB149.1.
The appliance, when installed, must be
electrically grounded in accordance with local
codesor,intheabsenceoflocalcodes,withthe
National
ElectricalCode,ANSI/NFPA70.
If local codes permit, a flexible metal appliance
connection with the new AGA or CGA certified
design, max. 5 feet (1,5 m) long, ½” I.D. is
recommended for connecting this appliance to
the gassupply line.Do notbend or damagethe
flexibleconnectorwhenmovingthe
appliance.
This appliance must be used with the pressure
regulator pr ovided. The regulator shall be
properlyinstalledinordertobe accessiblewhen
theapplianceisinstalledinitsfinallocation.The
pressureregulatormustbesetforthetypeofgas
tobeused.Thepressurer egulatorhas½”
female
pipe thread. The appropriate fitting must be
determinedbasedonthesizeofyourgas supply
line,theflexiblemetalconnectorandtheshutoff
valve.
The appliance must be isolated from the gas
supply piping system by closing its individual
manualshutoffvalveduringanypressuretesting
ofthegas
supplypipingsystemattestpressures
equaltoorlessthan½psi(3.5kPa).
Allopeningandholes inthewall andfloor,back
and under the appliance shall be sealed before
installationoftheappliance.
Amanualvalveshallbeinstalledinanaccessible
locationinthegas
lineexternalto theappliance
forthepurposeofturning onorshutting offgas
totheappliance
WARNING!
Donotuseaerosolspraysinthevicinityofthis
appliancewhileitisinoperation
ROOM VENTILATION: An exhaust fan may be
used withthe appliance; in eachcase it
shall be
installed in conformity with the appropriate
national and local standards. Exhaust hood
operationmayaffectotherventedappliances;in
eachcase itshallbe installedinconformitywith
theappropriatenationalandlocalstandards.
TYPEOFGAS
Thisapplianceisshippedfromthefactoryforuse
with natural
gas. For use with propane lp gas
please follow the conversion procedure
described on pg. 17. A step by step conversion
procedureisalsoincludedwitheachsetoflpgas
nozzles.
GASPRESSURE
Themaximuminletgassupplypressureincoming
to the gas appliance pressure regulator is 20’’
water
column(5kPa).
The minimum gas supply pressure for checking
theregulatorsettingshall beatleast1“w.c.(249
Pa)abovetheinletspecifiedmanifoldpressureto
the appliance (this operating pressure is 4” w.c.
(1.00kPa)forNaturalGasand11”w.c.(2.75kPa
forLPGas).