Bertazzoni PRO366GASXLP Range User Manual


 
14
PRESSUREREGULATOR
Sinceservicepressuremayfluctuatewithlocal
demand,everygascookingappliancemustbe
equippedwithapressureregulatoronthe
incomingservicelineforsafeandefficient
operation.
Thepressureregulatorshippedwiththe
appliancehashastwofemalethreads½”NPT.
Theregulatorshallbeinstalled
properlyinorder
tobeaccessiblewhentheapplianceisinstalledin
itsfinalposition.
Manifoldpressureshouldbecheckedwitha
manometerandcomplywiththevaluesindicated
below:
Naturalgas4.0"W.c.P.
LP/Propane11.0"W.C.P.
Incominglinepressureupstreamfromthe
regulatormustbe1"W.c.P.higherthanthe
manifoldpressureinordertocheckthe
regulator.
Theregulatorusedon
thisrangecanwithstanda
maximuminputpressureof1/2PSI(14.0"W.c.P.)
Ifthelinepressureexceedsthatamount,astep
downregulatorisrequired.
Theappliance,itsindividualshutoffvalve,and
the pressure regulator must be disconnected
from the gas line during any pressure testing of
thatsystem
atpressures inexcess of 1/2psig
(3.45kPa).
The individuaLmanual shutoffvalve must bein
theOFFpositionduring anypressuretestingof
the gassupply pipingsystem attestpressures
equaltoorlessthan½psig(3.45kPa).