Bertazzoni X)486GPIRCR Range User Manual


 
12
INSTALLING THE ANTITIP Stability DEVICE
The antitip bracket shipped with the range must
be properly secured to the rear wall as shown in
the picture below.
The height of the bracket from the floor must be
determined after the range legs have been
adjusted to the desired height and after the
range has been levelled.
Measure the distance from the floor to the
bottom of the antitip bracket receptacle on the
back of the appliance.
Position the two antitip brackets on the wall at
the desired height plus 1/8" (0.32 cm). The
brackets must be placed at 2”5/16 (6,0 cm) from
the side of the range. The distance between the
two bracket is 43”1/4 (109,8 cm).
Secure the brackets to the wall with appropriate
hardware.
Slide the range against the wall until the brackets
are fully inserted into their receptacles on the
back of the range.
INSTALLATION REQUIREMENTS
ELECTRICAL
A properly grounded and horizontallymounted
electrical receptacle Type NEMA 1450R should
be installed no higher than 3" (7.6 cm) above the
floor, no less than 2” (5 cm) and no more than 8”
(20,3 cm) from the right side (facing product);
refer to ELECTRICAL CONNECTION section pag.
13.
Check all local code requirements.
GAS
An agencyapproved, properlysized manual shut
off valve should be installed no higher than 3"
(7.6 cm) above the floor and no less than 2” (5
cm) and no more than 8” (20.3 cm) from the left
side (facing product).
To connect gas between shutoff valve and
regulator, use agencyapproved, properly sized
flexible or rigid pipe. Check all local code
requirements.