Blanco BID11 Dishwasher User Manual


 
23
EN
13/
IF OPERATING ABNORMALITIES OCCUR
BEFORE CALLING FOR SERVICE
Problem Possible Causes What to do?
The door falls heavily when
opened (integratable model)
- Door springs not tensioned
enough to compensate for the
weight of the panel.
- Tighten the two tensioning
screws accessible in the bot-
tom section above the front
feet.
The door does not stay horizontal
when open or returns too
quickly
(integratable model)
- Door springs tensioned too
much.
- No wooden panel.
- Loosen the two tensioning
screws accessible in the bot-
tom section above the front
feet.
- Fit a temporary wooden panel
on the appliance and adjust
the springs.
The door catches when closing - Appliance not stable
- Door not centred on the tub
- Adjust the feet.
- Re-centre by adjusting the
rear feet.
The upper basket does not stay
in the high position
- Poor manipulation (the basket
is being pulled upwards too
quickly)
- Act more progressively (see
instructions), one side and
then the other.
Small leak around or under the
appliance (move the appliance
to locate the leak)
- Leak from the tap.
- Leak from the appliance.
(Cf. table fault d07).
- Check that a seal is fitted and
retighten the nut.
- Close the water tap and call a
technician.
Small leak at the door
- Appliance not stable or not level
- Door not centred on the tub.
- Adjust the feet.
- Re-centre by adjusting the rear
feet.
SUMMARY OF THE FAULTS
Flashing LED(s)
for models without a display
Flashing LED(s)

d01 : water supply fault (tap) d07 : overflow / anti-leak fault


d02 : draining fault
d08 : sprinkling distribution fault



d03 : heating fault d11 : pressure sensor fault


d04 : temperature fault
d12 : filling fault (water inlet
detection system)


d05 : fault – motor under load d13 : overheating fault


d06 : fault - motor overload
d14 : pump filling fault or insuffi-
cient flow from the water tap.
