HEATER ELEMENTS DO NOT COME ON
When the steamer is turned ON and heater elements do not activate, and the READY
light does not come on, then the contactors may be burned out. If a considerable
amount of “chattering” of contactors has been previously experienced, then the
thermostat bulb may be coated with scalant and unable to sense water temperature in
the boiler accurately, and therefore unable to control the contactors.
1. Replace contactors.
2. Unscrew thermostat bulb, clean off scalants and screw thermostat bulb back in.
This problem may be an indication of inadequate water quality and is not covered under
warranty. Have water quality analysed and corrected immediately to avoid complete
malfunction of the steamer.
UNIT SHUTS DOWN WHILE IN OPERATION
Pressure switch has been activated due to 5 psi (34 kPa) pressure in the generator tank.
Pressure in the generator tank is caused by plugged steam jet tubes or steam diverters,
due to scale or poor water conditions. Steam jet tubes/steam diverter will have to be
cleaned or replaced.