Safety
English 3
• The maximum supply pressure must not exceed 14.0 inches water column
(34.9Millibars).
• This appliance has been CSA certified for safe operation up to a height of
10,000 ft. without any modifications. Exception: For use with propane the
appliance must be converted per the LP conversion instructions.
• For Massachusetts installations:
• Installation must be performed by a qualified or licensed contractor,
plumber or gas fitter qualified or licensed by the state, province or region
where this appliance is being installed.
• Shut-off valve must be a "T" handle gas cock.
• Flexible gas connector must not be longer than 36 inches.
• Installer - show the owner where the gas shut-off valve is located.
Propane Gas Installation • The propane gas tank must be equipped with its own high pressure regulator.
In addition, the regulator supplied with this unit must also be used.
• The appliance is shipped from the factory for use with natural gas. It must be
converted for use with propane. A qualified technician or installer must do the
conversion.
Figure 2: Gas Precautions
WARNING: If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury or death.
• Do not store or use combustible materials, gasoline or other flammable
vapors and liquids in the vicinity of this or any other appliance
• WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow
the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department. Instal-
lation and service must be performed by a qualified installer, autho-
rized service agency or the gas supplier.