Bunn A10 Coffeemaker User Manual


 
7
CAUTION - Do not plug-in the brewer until specified in Initial
Set-Up.
The A10/A10 Automatic Brewer has an attached cordset and
requires 2-wire grounded service rated 120 volts ac, 10 amp,
single phase, 60 Hz.
The A10A/A10A Automatic Brewer has an IEC 320 connector
and matching cordset and requires 2-wire grounded service rated
230 volts ac, 10 amp, single phase, 50-60 Hz. The appropriate
cordset connector must be supplied when installing the brewer.
CONTINUED
PLUMBING REQUIREMENTS - A10 AUTOMATIC ONLY
This brewer must be connected to a cold water system with operating pressure between 20 and 90
psi from a 1/2” or larger supply line. A shut-off valve should be installed in the line before the brewer.
Install a regulator in the line when pressure is greater than 90 psi to reduce it to 50 psi. The water inlet
ttingis1/4”are.
NOTE – Bunn-O-Matic recommends
1
/
4
” copper tubing for installations of less than 25 feet and
3
/
8
” for more
than 25 feet from the
1
/
2
” water supply line. At least 18 inches of an FDA approved flexible beverage tubing,
such as reinforced braided polyethylene or silicone, before the brewer will facilitate movement to clean the
countertop. It can be purchased direct from Bunn-O-Matic (part number 00326-0000).
As directed in the International Plumbing Code of the International Code Council and the Food Code Manual of
the Food and Drug Administration (FDA), this equipment must be installed with adequate backflow prevention to
comply with federal, state and local codes. For models installed outside the U.S.A., you must comply with the
applicable Plumbing /Sanitation Code for your area.
Plumbing Hook-Up
1. Attachthearettingfromtheshortpieceoftubingontheowcontrol(supplied)tothewaterinlet
fitting on the left rear side of the brewer.
2. Flushthewaterlineandsecurelyattachittothearettingonthestrainer.
3. Turn on the water supply.
CE REQUIREMENTS
•Thisappliancemustbeinstalledinlocationswhereitcanbeoverseenbytrainedpersonnel.
•Forproperoperation,thisappliancemustbeinstalledwherethetemperatureisbetween5°Cto35°C.
•Applianceshallnotbetiltedmorethan10°forsafeoperation.
•Anelectricianmustprovideelectricalserviceasspeciedinconformancewithalllocalandnational
codes.
•Thisappliancemustnotbecleanedbywaterjet.
•Thisapplianceisnotintendedforusebypersons(includingchildren)withreducedphysical,sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given instructions
concerning use of this appliance by a person responsible for its safety.
•Childrenshouldbesupervisedtoensuretheydonotplaywiththeappliance.
•Ifthepowercordiseverdamaged,itmustbereplacedbythemanufacturerorauthorizedservice
personnel with a special cord available from the manufacturer or its authorized service personnel in
order to avoid a hazard.
•Machinemustnotbeimmersedforcleaning.
ELECTRICAL REQUIREMENTS
120 VOLT 230 VOLT CE
43422.1 010311