AUTO-FILL SET UP INSTRUCTIONS
1. Remove right side panel.
4. Install snap clamps on hoses,
just above the bushings to pre-
vent hoses from being pulled
loose from the solenoid valves.
2. Remove hole plugs in bottom
of machine to route hoses to
valves.
3. Connect and properly clamp
supply product and water lines
from Brix pumps. Ensure that
all connections are made to
the correct valve for the right
or left hopper. All valves are
labeled to help with this pro-
cess.
5. Route the tubes from the sole-
noids up to the quicck discon-
nect fittings on the hoppers.
The tubes are supplied with
extra length to allow for trim-
ming if desired. Slip a clamp
over the end of the tube and
install a .25" male disconnect
fitting. Position the clamp over
the barb area of the fitting and
crimp into place.
NOTE: Make certain the tubes are
routed to the correct hoppers tp
prevent product from being mixed
or hoppers overflowing. Connect
the tubes to the hoppers.
7. Install hopper level probe onto
hopper.
6. Connect the tubes to the hop-
pers.