29
8. Apply power to machine and turn water on for Brix Pump operation. Refer to the Programming section of
this manual in the Refill Threshold section to check refill for proper operation.
9. At the threshold screen, with no product in the hopper, confirm the number on the left (top) of the screen
is around 250. The number on the right of the screen is factory set to 155. The factory set point should not
need any adjustment.
10. After confirming that both hoppers are reading about 250 for the threshold, proceed to the next screen to
test the refill circuit.
11. At the test refill screen, select yes.
12. The Activate Valve screen will allow you to tset the pumping and refill circuit. Press and hold the ULTRA
button to activate the left refill system. Confirm that the left side is filling when the ULTRA button is
pressed. Release the ULTRA button to stop the filling process. Repeat this process for the right side by
pressing the ICE button to test. Check for leaks at the hoses while pumping system is running.
13. Once the testing is complete, exit the programming menu and reinstall the right side panel.
14. The auto fill feature can be turned on by pressing the auger button for each side until the display reads
“AUGER REFILL ON”.
AUTO-FILL SET UP INSTRUCTIONS (cont.)
32080.0001 081006