Bunn Dual SH Coffeemaker User Manual


 
Page 11
29877 121302
PROGRAMMING THE BREWER (cont.)
PROGRAM FUNCTIONS - LEVEL 2
There are three methods of programming the
various brewing parameters of the Dual
®
SH with
Smart Funnel
®
Brewer.
METHOD 1:
Using a Smart Funnel
®
and a G9-2T DBC Grinder:
Certain coffee NAMES are stored in the G9-2T
DBC's memory. When a particular name of coffee is
ground into the Smart Funnel
®
, that name and the
batch size selected are transferred from the grinder to
the programming chip located in the funnel's handle.
The funnel is then inserted into the brewer's left side
funnel rails. The sensor coil on the brewer reads the
information contained in the handle. This then allows
the operator to set the BREW VOLUMES, BYPASS
PERCENTAGES, PULSE BREW TIMES, PREINFUSION
TIMES and DRIP-OUT TIMES for that particular coffee
NAME. Each coffee NAME can be set individually to
provide optimum brewing quality.
METHOD 2:
Using a RECIPE CARD to enter all of the brew
settings at one time:
If using a coffee name not in the G9-2T DBC's
memory, the customer can obtain a RECIPE CARD
from the factory with all the information needed to set
up that particular coffee flavor. This includes the
COFFEE NAME, BREW VOLUMES, BYPASS PER-
CENTAGES, PULSE BREW TIMES, PREINFUSION
TIMES, and DRIP-OUT TIMES.
METHOD 3:
Not using a Smart Funnel
®
and/or a G9-2T DBC
Grinder:
This allows the operator to enter ONE set of
brewing parameters for each side, in the event a Smart
Funnel
®
and/or a G9-2T DBC is not used with the Dual
®
SH Brewer. This is referred to as a NO NAME coffee
flavor. If the brewer does not read the information in
the funnel's handle, it automatically selects the NO
NAME brewing parameters set up prior to brewing.
This includes the BREW VOLUMES, BYPASS PER-
CENTAGES, PULSE BREW TIMES, PREINFUSION
TIMES and DRIP-OUT TIMES for the three batch sizes.