PROBLEM:
LIQUID LEVEL CONTROL SYSTEM DOES NOT REFILL
PROBLEM:
LIQUID LEVEL CONTROL OVERFLOWS
RETRY
NO
YES
YES
NO
YES
REPLACE
CONTROL
ASSEMBLY (1)
DRAIN CUP
(4)
OVERFLOW
?
OVERFLOW
?
NO
OVERFLOW
?
REPLACE SOLENOID
VALVE (14)
DRAIN CUP (4)
DISCONNECT WIRE
SOLENOID VALVE (14)
FROM
RETRY
REPLACE PROBE (7)
DRAIN CUP (4)
DISCONNECT PROBE
WIRE FROM PROBE (7)
SHORT PROBE WIRE
TO CHASSIS
RETRY
Liquid Level Control Test Procedure:
1. Disconnect brewer from the power source.
2. Check the voltage across terminals 3 & 4 of the
electronic control assembly (1) with a voltmeter.
Connect brewer to power source. The indication
must be:
a.) 208 volts ac for three wire 120/208 volt mod-
els and 240 volts ac for three wire 120/240 volt
models.
b.) 200 to 240 volts ac for two wire 200 or 240 volt
models.
ELECTRONIC CONTROL ASSEMBLY (cont.)
P808
P809
BREW START- LOCK
The water must be heated to the preset tempera-
ture indicated by the glowing ready light before a brew
cycle can be initiated.
If the ready light goes out during a brew cycle, the
cycle will continue until it is completed. You must wait
until the ready light glows before starting another
brew cycle.
OVERFLOW CUP FULL
YES
REMOVE POWER
DRAIN CUP
RETRY
NO
DISCONNECT LEVEL PROBE
(4)
(4)
(7)
VOLTAGE PRESENT AT
SOLENOID VALVE
(14)
YES
DOES WATER FLOW
YES
REPLACE PROBE
(7)
NO
NO
REPLACE
SOLENOID VALVE
(14)
REPLACE
CONTROL
ASSEMBLY (1)