Page 7
Remedy
(A) Direction of flow arrow must be
pointing towards brewer.
(B) Remove the strainer/flow con-
trol and check for obstructions. Clear
or replace.
Refer to
Service
- ON/OFF switch for
testing procedures. See page 28
Refer to
Service -
Start switch for
testing procedures. See page 34
Refer to
Service -
Timer for testing
procedures. See page 36 or 38
Refer to
Service -
Dispense valve for
testing procedures. See page 19
Refer to
Service
- Control assembly
for testing procedures. See pages
20 thru 25
Refer to
Service
- Brew selector
switch for testing procedures. See
page 14
Refer to
Service
- Server sensor for
testing procedures. See page 29
Check plumbing and shut-off valves.
(A) Direction of flow arrow must be
pointing towards brewer.
(B) Remove the strainer/flow con-
trol and check for obstructions. Clear
or replace.
Refer to
Service
- Solenoid valve for
testing procedures. See page 33
TROUBLESHOOTING (cont.)
Brew cycle will not start (cont.)
Automatic refill will not operate
Problem
Probable Cause
3. Water strainer/flow control (.750
GPM)
4. ON/OFF switch
5. Start switch
6. Timer
7. Dispense Valve
8. Control Assembly (Electronic)
9. Brew selector switch
10. Server sensor
1. No water
2. Water strainer/flow control (.750
GPM)
3. Solenoid Valve (Inlet)
27124 062100