Bunn JDF-2S Beverage Dispenser User Manual


 
6
FIG 3 Initial Fill Connection
INITIAL FILL
CAUTION: The dispenser must be disconnected from the
power source throughout the initial fill except when speci-
fied in the instructions.
1. Remove drip tray assembly and splash panel from the
dispenser. Replace the drip tray.
2. Connect the water source to the back of the dispenser.
3. Pull the fill tube from the dispenser, remove the plug and
connect it to the dispense nozzle.
4. Place the Dispense Lockout switch in the OFF position.
5. Connect dispenser to the power source. Press and hold
the dispense button for the dispense station that the tube
is connected to for 10 seconds, until you hear the water
valve turn on.
6. Monitor the water bath fill level until water starts to trickle
from the overflow tube. Then press the dispense button
again to stop the fill process.
7. Turn ON the refrigeration switch at the back of the dis-
penser. This will start the water bath pump circulation.
8. Check water level in the overflow tube and top off the
tank if necessary (Step 5).
9. Disconnect the fill tube and allow excess water to drain
into the drip tray. Replace the plug in the end of the fill
tube and store back into the dispenser.
10. Place the Dispense Lockout switch back to the ON posi-
tion.
11. Replace the splash panel and drip tray.
12. It will take approximately three hours at 75° F (24° C)
ambient to create the ice bank required for full dispenser
performance. During this time, some further trickling
from the water bath is expected due to expansion caused
by ice bank formation. While the refrigeration system is
creating the ice bank, the dispenser may be readied for
use as described in Loading, Priming and Adjustment.
FIG 1 Plumbing Connections
PLUMBING HOOKUP
The plumbing connection is located on the rear of the
dispenser. A 3/8” (9.52 mm) male flare adapter fitting is
supplied, installed on the rear of the dispenser.
P3580-1
FIG 2 Initial Fill Hose
P3582
P3581-1
38945 050106