Bunn LCC-2 Beverage Dispenser User Manual


 
15
Right (Decaf) Dispense Total
LCD DISPLAY PROGRAM MODE DESCRIPTION
PROGRAMMING THE DISPENSER (Cont.)
Program Mode (Continued)
Empty Product Threshold Set Conductance Threshold
Default = 600
Range = 100 Min / 900 Max
To check Conductance of Hot Water,
view the display while rinsing. Set value
to 100 above reading.
Displays Software Version # -
Exits To Home View After 3 Seconds.
Rinse Alarm Timer Default = OFF > Rinse Alarm Disabled
Range = 1 - 24 hrs
Reminder Only. No Lock Out.
To clear alarm, set to RINSE Mode.
Press Left switch, then Right switch
for 15 seconds each.
39288 070109
Reset Total to Zero (00.0 Gal)
(0.00 Liters)
MENU (-) (+)
P 7 00.
MENU (-) (+)
P 8
6
0 0
MENU (-) (+)
O
P 9 F F
MENU (-) (+)
L C x x0
Program Lockout Function: The operator must hold down the stop and portion control button for 10 sec-
onds while machine is in program mode. At 10 seconds, the machine's display changes from "PPP" to "PP LOC"
indicating the locked position. At this point, the operator may view the setup functions, but not alter any of the
parameters. In order to unlock the machine, repeat the aforementioned process. A MemoryLocked flag is set in
eeprom so that the machine will retain this setting if power is lost.
Function Lockout Feature
Prevents the user from changing set-up
functions
LCD DISPLAY PROGRAM FUNCTION DESCRIPTION
MENU (-) (+)
PP L
O
C