Bunn LCR-1 Coffeemaker User Manual


 
20
TROUBLESHOOTING GUIDE (Cont.)
Error Codes (Continued)
LED DISPLAY ERROR DESCRIPTION/TROUBLESHOOTING
Cooling Time Too Long
Cabinet Sensor has not reached the
set point in 4 hours.
Check: Air Filter plugged or blocked.
Cabinet door left open or faulty seal.
Wiring for shorts or open connections.
Evaporator iced up.
Ambient operating temperature is
greater than 95°F (35°).
Cool Temp Sensor Failed
MENU (-) (+)
6
E
_ 0
MENU (-) (+)
7
_ 0
Sensor reading Out Of Range (High or
Low).
Check Sensor wires for shorts or open
connections.
The Follow errors codes apply to the LCR-1 only.
E
44806.1 081211