Bunn S/N CDBC020213 Coffeemaker User Manual


 
Page 21
The bank of temperature indicators indicates that a fault exists. Count the number of flashes between pauses and
use this chart as a guide to investigating the fault.
FLASHES CAUSE THINGS TO CHECK
1 Dry Plug - In Fault - Water Pressure (Is water shut "OFF")
Sheath of temperature probe dry for 10 minutes after power-up Temperature probe wiring
Fill valve wiring, function, & strainer
Green wire between tank and circuit board
2 Low Tank Level Fault - Water pressure (Is water shut "OFF")
Level probe dry for 7 minutes after fill valve is energized Level probe wiring
Temperature probe wiring
Fill valve wiring, function, & strainer
3 Low Water Temperature Fault - Tank heater wiring & function
Sensor in tank is calling for heat for 30 minutes or more Temperature probe wiring
4 Tank Sensor Disagreement - Temperature probe wiring
Level probe detects water, but dry plug-in probe dry Level probe wiring
Green wire between tank and circuit board
5 Temp Sensor Out-of-Range - High Sensor not connected to circuit board
6 Temp Sensor Out-of-Range - Low Sensor wires shorted together or to chassis
DIAGNOSTICS
35582 041503