Bunn SRUA Coffeemaker User Manual


 
Page 10
TROUBLESHOOTING (cont.)
PROBLEM
Water running out of the overflow
Water is not hot
Fuse Opening
PROBABLE CAUSE
1. Brewer not level
2. Solenoid Valve
3. Liquid Level Board
4. Probe
1. Limit Thermostat
CAUTION - Do not eliminate or
bypass limit thermostat. Use only
Bunn-O-Matic replacement part
#29329.1000.
2. Control Thermostat
3. Tank Heater
4. Contactor
5. Thermal fuses
1. Fuse
2. Tank Heater
REMEDY
Brewer must be level and installed
on a sturdy structure.
Refer to
Service
- Solenoid Valve
for testing procedures. See page
23
Refer to
Service
-Liquid Level
Board for testing procedures. See
page 18
Refer to
Service
- Probe for test-
ing procedures. See page 18
Refer to
Service
- Limit Thermo-
stat for testing procedures. See
page 17
Refer to
Service
- Control Ther-
mostat for testing procedures. See
page 15
Refer to
Service
- Tank Heater for
testing procedures. See page 26
Refer to
Service
- Contactor for
testing procedures. See page 14
Refer to
Service -
thermal fuses
for testing procedures. See page
27
Refer to
Service -
Fuse for testing
procedures. See page 16
Refer to
Service
- Tank Heater for
testing procedures. See page 26
10067.3 070102