Bunn SRUA Coffeemaker User Manual


 
Page 9
TROUBLESHOOTING (cont.)
PROBLEM
6. Start Switch
7. Timer
8. Pump
9. Solenoid Valve
10. Strainer
1.ON/OFF Switch (This switch must
be in the "ON" position for the refill
circuit to operate.
2. No water
3. Solenoid Valve
4. Probe
5. Liquid Level Board
Refer to
Service
- Start Switch for
testing procedures. See page 24
Refer to
Service
- Timer for testing
procedures. See page 28 or 29
Refer to
Service
- Pump for testing
procedures. See page 21
Refer to
Service
- Solenoid Valve for
testing procedures. See page 23
(A) Direction of flow arrow must be
pointing towards brewer.
(B) Remove the strainer and check
for obstructions. Clear or replace.
Refer to
Service
- ON/OFF Switch for
testing procedures. See page 20
Be sure water shut-off is open and
that in-line filters or strainers are not
blocking water flow.
Refer to
Service
- Solenoid Valve for
testing procedures. See page 23
Refer to
Service
- Probe for testing
procedures. See page 18
Refer to
Service
- Liquid Level Board
for testing procedures. See page 18
Brew cycle will not start (cont.)
Tank not filling
PROBABLE CAUSE
REMEDY
10067.3 070102