Bunn TS Coffeemaker User Manual


 
Page 5
Models CWTFA-APS & CWTFA-TS
1. Attach the flare fitting from the short piece of
tubing on the flow control (supplied) to the lower
water inlet fitting at the left rear of the brewer.
2. Attach the flare fitting from the short piece of
tubing on the tee (supplied) to the upper water
inlet fitting at the left rear side of the brewer.
3. Flush the water line and securely attach it to the
flare fitting on the tee.
4. Turn on the water supply.
5. Place an empty vessel beneath the faucet and lift
the handle until water is dispensed.
PLUMBING REQUIREMENTS (cont.)
10690.1 063000
INITIAL SET-UP
CAUTION - The brewer must be disconnected from the power source throughout the initial set-up, except
when specified in the instructions.
1. Insert an empty funnel into the funnel rails.
2. Place an empty dispenser under the funnel.
3. Place the heater switch at the rear of the brewer in the OFF (lower) position and connect the brewer to the
power source.
4. Fill the tank with water as directed:
4A. Models CWA-APS & CWA-TS:
Pour three pitchers of tap water into the screened area on top of the brewer. Allow approximately two minutes
between pitchers for water to flow into the tank. While the third pitcher of water is entering the tank, the tank
will fill to capacity and the excess will flow from the sprayhead, out of the funnel, and into the dispenser.
4B. Models CWTA-APS, CWTFA-APS, CWTA-TS & CWTFA-TS:
Connect the brewer to the power source, place the "ON/OFF" switch in the "ON" (upper) position, and
momentarily press and release the START switch. Water will begin flowing into the tank. When water stops
flowing into the tank, initiate a second and a third brew cycle. During the third brew cycle the tank will fill to
its capacity and the excess will flow from the sprayhead, out of the funnel, and into the dispenser.
5. When the flow of water from the funnel stops, place the heater switch at the rear of the brewer in the ON
(upper) position and wait approximately twenty minutes for the water in the tank to heat to the proper
temperature. Some water will drip from the funnel during this time; this is due to expansion and should not
occur thereafter.
6. Empty the dispenser and initiate another brew cycle as directed:
6A. Models CWA-APS & CWA-TS:
Pour one pitcher of tap water into the screened area on top of the brewer.
6B .Models CWTA-APS, CWTFA-APS, CWTA-TS & CWTFA-TS:
Place the "ON/OFF" switch in the "ON" (upper) position, and momentarily press and release the START switch.