Bunn TU5Q Coffeemaker User Manual


 
Page 22
SERVICE (cont.)
TANK HEATER
FIG. 20 TANK HEATER
Location:
The tank heater is located inside the tank and se-
cured to the tank lid.
Test Procedures:
1. Disconnect the brewer from the power supply.
2. With a voltmeter, check the voltage across the
black and white or red wires. Connect the brewer
to the power source. The indication must be:
a) 120 volts ac for 2-wire 120 volt models.
b) 208 volts ac for 3-wire 120/208 volt models.
c) 240 volts ac for 3-wire 120/240 volt models.
3. Disconnect the brewer from the power source.
If voltage is present as described, proceed to #4
If voltage is not present as described, refer to the
Wiring Diagram
and check wiring harness.
4. Disconnect the black wire and the white or red
wire from the tank heater terminals.
5. Check for continuity across the tank heater termi-
nals.
If continuity is present as described, reconnect the
wires, the tank heater is operating properly.
P2143.35
If continuity is not present as described, replace the
tank heater.
NOTE- If the tank heater remains unable to heat, re-
move and inspect heater for cracks in the sheath.
Removal and Replacement:
1. Disconnect the black wire and the white or red
wire from the tank heater terminals.
2. Remove sprayhead and the hex nut securing the
sprayhead tube to the hood. Set aside for reas-
sembly.
3. Disconnect vent tube and water inlet tube.
4. Remove the eight #8 keps nuts securing the tank
lid to the tank.
5. Remove the tank lid with limit thermostat, spray-
head tube, tank heater and vent tube.
6. Remove the two hex nuts securing the tank heater
to the tank lid. Remove tank heater with gaskets
and discard.
7. Install new tank heater with gaskets on the tank
lid and secure with two hex nuts.
8. Install tank lid with limit thermostat, sprayhead
tube, tank heater and vent tube using eight #8 keps
nuts.
9. Secure sprayhead tube to hood using a hex nut.
10. Install sprayhead.
11. Connect vent tube and water inlet tube to fitting.
12. Reconnect the wires to the limit thermostat and
tank heater. See limit thermostat section in this
manual when reconnecting wires.
13. Refer to Fig. 21 when reconnecting the tank heater
wires.
FIG. 21 TANK HEATER TERMINALS
P1284.80
BLK to Control
Thermostat
WHI to Terminal
Block (120V)
RED to Terminal
Block (208&240V)
10777 041500
4
2
3
1
MINUTES
MINUTES
BUNN-O-MATIC
BUNN-O-MATIC
P/N 05791-0006 120 VAC
5
3
6
4
7
5
6
6
7
8