Cannon Professional Cooktop User Manual


 
28
TECHNICAL DATA
DIMENSIONS
Height 900 - 915 mm
Widht 1000 mm
Depth 600 mm (excluding door handles)
GENERAL
Gas connection Rp ½ (½" BSP female)
Pressure test point Hotplate burner injector
Gas rate adjustment None
Aeration adjustment None
Electrical connection Flexible cord fitted with a 13A plug 230-240V~ 50Hz. 3A fuse.
INSTALLATION INSTRUCTIONS
230-240V~
Cat I2H
G20 at 20 mbar
BURNER
HEAT INPUTHEAT INPUTINJECTOR
HOTPLATE
Front Left
1.90 kW 102 Z
HOTPLATE
Rear Left
3.00 kW 116 Y
HOTPLATE
Centre Front
4.10 kW 110 x 2
HOTPLATE
Centre Front
1.00 kW 74
HOTPLATE
Centre Rear
1.00 kW 71 X
HOTPLATE
Front Right
1.50 kW 88 X
HOTPLATE
Rear Right
1.50 kW 88 X
GRILL 3.90 kW 128 Y
L
EFT OVEN 2.60 kW 123
RIGHT OVEN 2.60 kW 123
WARMING
DRAWER
0.15 kW