CONNECTING TO GAS SUPPLY
Connection to the cooker should be made with an approved appliance flexible
connection to BS 669. A length of 0.9 to 1.25m is recommended. The length of hose
chosen should be such that when the cooker is in situ, the hose does not touch the
floor.
Those cookers converted to use on LPG should be connected with a hose suitable for
LPG and capable of withstanding a pressure of 50 mbar.
An adaptor backplate should be fitted within the shaded area shown, to allow the
cooker to be pushed fully to the wall and to ensure that the flexible hose is only likely
to come into contact with areas at the rear of the cooker that do not exceed a
temperature rise of 70˚C.
32
INSTALLATION INSTRUCTIONS
300
670
18. Remove the 6 screws securing the timer mounting panel. Without completely
removing it, manoeuvre the timer mounting panel to gain access to the thermostat
bypass screws.
19. Using a narrow flat bladed screwdriver rotate the bypass screws fully clockwise. The
main oven thermostat bypass screw is located on the body of the thermostat below
the spindle, the top oven thermostat bypass screw is located on the body of the
thermostat to the right of the spindle and the hotplate tap bypass screws are located
down the centre of the spindle.
20. Re-assemble the control panel parts.
21. Secure the self-adhesive LPG conversion label over the gas details on the data badge.
STABILITY CHAIN
A hole in the gas inlet valve bracket can be used to engage a stability chain.