This cooktop can be built into a working surface 20 to 40 mm thick and 600 mm deep.
In order to install the ceramic hob into the kitchen fixture, a hole with the dimensions shown in figure 8
has to be made, keeping in consideration the following:
– Within the unit, between the bottom of the hob and the upper surface of a shelf there must be a
clearance of at least 30mm (fig. 9).
– It is absolutely essential that you place a separator between the base of the hob and the built-in unit.
– If the hob is installed over a built-in oven, there must be a distance of at least 30mm between the two
appliances. The oven shall be provided with cooling fan. The two appliances should be connected to the
electrical supply with independent connections.
– The ceramic hob must be kept no less than 50 mm away from any side wall.
– The rear wall must be at least 50 mm from the ceramic hob.
– There must be a distance of at least 650 mm between the hob and any wall cupboard or extractor hood
positioned immediately above (see fig. 10).
– The coatings of the walls of the unit or appliances near the cooktop must be heat resistant.
– Do not install the appliance near inflammable materials (eg. curtains).
30 mm
Space for
connections
Clearance
Separator
Fig. 9
500 mm
650 mm
450 mm
Fig. 10
50 mm minimum between the side of
the cut-out and the side wall