10
TEMPERATURE SENSOR CALIBRATION TEMP SENSOR CAL
ARE YOU SURE ?
Description – The Temperature Sensor Calibration allows the user to offset (calibrate) the displayed water
temperature to a reference thermometer.
Instructions – Use the [Arrow] Keys to adjust (calibrate) the displayed
temperature to match the reference thermometer. Depress one of the
[Hidden] Keys when the calibration is complete.
TEMP SENSOR CAL
### °F
LOCKOUT TEMPERATURE LOCKOUT TEMP
### °F
Description – The Lockout Temperature is the minimum brewing temperature. The system will not allow a
Brew Cycle to begin unless the water is above the Lockout Temperature.
SLEEP TIMER SLEEP TIMER
ON/OFF
Description – The Sleep Timer feature automatically reduces the water temperature to three degrees above
the Lockout Temperature if the machine has not started a Brew Cycle within two hours.
WARMER POWER WARMER POWER
### %
Description – The Warmer Power feature allows the user to reduce the actual heating power of the
warmers. The percentage displayed is percentage of maximum power.
WARMER TIMER WARMER TIMER
ON/OFF
Description – The Warmer Timer feature allows the user to set the maximum length of time a brew remains
fresh while being warmed. Once the Warmer Timer has expired an alarm is generated. An alarm consists
of a blinking warmer LED and (optionally) the audible alarm (buzzer) sounding. The Warmer Timer is reset
(restarted) by cycling the warmer Off and On.
AUDIBLE ALARM AUDIBLE ALARM
ON/OFF
Description – The Audible Alarm feature allows the user to enable/disable the buzzer from indicating that
the Warmer Timer has expired.
WARMER TIME WARMER TIME
### MINUTES
Description – The Warmer Time is the length of time that a warmer can be continuously energized before
an alarm is generated.
WARMER REDUCTION WARMER REDUCTION
ON/OFF
Description – The Warmer Reduction feature allows the user to gradually reduce the actual heating power
of the warmers. This reduction of power is taken over the Warmer Timer period.
REDUCTION PERCENTAGE REDUCTION PCT
### %
Description – The Reduction Percentage is the percentage of Warmer Power that is gradually reduced over
the Warmer Time.
WEEKDAY TIMER WEEKDAY TIMER
ON/OFF
Description – The Weekday Timer function allows the system to automatically turn ON at a specified time
and turn OFF at a specified time every weekday (Monday – Friday).
WEEKDAY TIME ON WEEKDAY TIME ON
##:## #M
Description – The Weekday Time ON function allows the user to set the required weekday turn ON time.