Dacor DMT2420S Microwave Oven User Manual


 
34
SPECIFICATIONS
DMT2420S, DMT2420B, DMT2420R
SERVICE CALL CHECK
Please check the following before calling for service:
Place one cup of water in a glass measuring cup in the oven and close the door securely.
Operate the oven for one minute at HIGH 100%.
A
Does the oven light come on? YES _______ NO _______
B
Does the cooling fan work? YES _______ NO _______
(Put your hand over the rear ventilating openings.)
C
Does the turntable rotate? YES _______ NO _______
It is normal for the turntable to turn in either direction.
D
Is the water in the oven warm? YES _______ NO _______
If “NO” is the answer to any of the above questions, please check electrical outlet, fuse and/or circuit breaker.
If they are functioning properly, CONTACT YOUR NEAREST DACOR AUTHORIZED SERVICER.
A microwave oven should never be serviced by a “do-it-yourself” repair person.
NOTE: If count-down time is appearing on the screen and counting down very rapidly, follow directions below
to cancel Hidden Demo.
Press STOP/CLEAR pad and hold for four seconds until an audible signal is heard.
Quickly press STOP/CLEAR key four times within the next two seconds.
AC Line Voltage:
AC Power Required:
Output Power:
Frequency:
Outside Dimensions:
Cavity Dimensions:
Oven Capacity:
Cooking Uniformity:
Weight:
Single phase 120V, 60Hz, AC only
1700 watts, 14.3 amps.
1200 watts* (IEC Test Procedure)
2450 MHz
24"(W) x 13
3
/
8
"(H) x 19
1
/
8
"(D)
17
3
/
8
"(W) x 10
1
/
2
"(H) x 18
5
/
8
"(D)
2.0 Cu. Ft.
Turntable system
Approx. 46 lb
* The International Electrotechnical Commission’s standardized method for measuring output wattage.
This test method is widely recognized.
In compliance with standards set by:
FCC –Federal Communications Commission Authorized.
DHHS –Complies with Department of Health and Human Services (DHHS) rule, CFR, Title 21, Chapter
I, Subchapter J.
This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc.
REGISTERED CORPORATION
1.DC/DMT2420 #323 11/14/02, 11:41 AM34