Gas Supply Connection
WARNING
Make sure the gas supply valve is off and that the power
to the range is turned off at the circuit breaker or fuse box
prior to connecting the gas line.
Do not apply excessive pressure when tightening gas
connections and fittings.
Do not use Teflon tape or plumber’s putty on gas flex line
connections.
For LP installations, the LP gas tank must have its own
high pressure regulator. This is in addition to the pressure
regulator provided with the range.
The maximum gas supply pressure to the regulator must
never exceed 1/2 pound per square inch (psi) or 3.5kPa.
The range and shut-off valve must be disconnected
from the gas supply piping during any pressure testing
exceeding 1/2 psi (3.5 kPa).
The range must be isolated from the gas supply piping by
closing the shut-off valve during any pressure testing at or
below 1/2 psi (3.5 kPa).
Check all gas lines for leaks as instructed to avoid a fire or
explosion hazard. Do not use a flame to check for leaks.
NOTE: The gas pressure regulator is pre-set at the factory for the
type of gas intended for use with the appliance. To verify that the
appliance is compatible with the type of gas available, check the
range data plate (see page 3 for location). Ranges intended for
use with LP gases will have “LP” as a part of the model number.
Consult your dealer if the range is not compatible with the type of
gas supplied.
Before sliding the range into the cabinet:
Make sure the gas supply valve is in the off position and that
power to the range is off.
Connect a flexible gas supply line to the gas shut-off valve
previously installed on the stub out. The gas line needs to be
long enough to allow the range to be pulled out for service.
Remove the gas regulator access cover.
Slide the end of the gas line under the back cover into the
regulator compartment from the bottom.
Connect the gas line to the regulator.
Turn all cooktop control valves to the “OFF” position. Turn on
the gas supply.
Check all lines
and connections
for leaks using a
soap and water
solution.
After verifying
that there are no
gas leaks, turn
off the gas supply
valve connected
to the range
to the “OFF”
position.
Replace the
regulator access
cover.
1.
2.
3.
4.
5.
6.
7.
8.
9.
Loop and
Spade Terminal
Connections
Bare Wire
Connections
10-50P Plug
L1
L2
Neutral
3 Wire Appliance
Cord Connection -
Where Local Code
Permits
Strain Relief
White Wire
L1 Wire
Neutral Terminal
L1 Terminal
L2 Terminal
L2 Wire
Jumper Link
Back Cover
Regulator
Connection
Gas Line
Installation Instructions