Dacor ERV3615 Ventilation Hood User Manual


 
10
Installation Instructions
Ground
Power
Input
Blower
Output
Electrical access
panel
Raised Vent
Electrical Access Panel
Raised Vent
Front View
To power wiring/conduit.
Connect other end of
wires to blower terminal
block.
Wires to power plug.
Pre-wired at factory.
Do not modify.
Attach ground wire
as shown
Match wire colors to
terminals as shown.
BLACK
WHITE
GREEN
Electrical Installation
WARNING
• ELECTRIC SHOCK HAZARD - Do not connect the
raised vent power plug to the electrical outlet until
installation is complete.
• Failure to complete electrical connections properly
may result in an electric shock hazard or a damaged
or non-functional system. Follow the wiring diagrams
carefully to ensure a proper installation. Do not
change the factory wired terminal connections inside
the electrical access panel for the raised vent or the
blower.
• To avoid an electric shock hazard and to prevent dam-
age route all wiring away from hot surfaces.
1. Run the wiring/conduit line used to supply power from
the raised vent to the blower parallel to the duct work.
2. Make sure the raised vent power plug is disconnected
from the electrical outlet.
3. Remove the cover from the raised vent electrical
access panel.
4. Connect the wiring/conduit to the blower according to
the wiring diagrams on this page, the facing page and
local codes and ordinances. Make sure all terminal
connections, including the factory wired connections,
are tight.
5. Replace the electrical access panel.