Dacor ERV3615 Ventilation Hood User Manual


 
12
Installation Instructions
Verifying Proper Operation
WARNING
• Read the raised vent use and care manual completely
before operation.
• Install all of the front filters prior to operating the raised
vent. Refer to the use and care manual for filter instal-
lation instructions.
CAUTION
To prevent damage to the raised vent power cord, route
it away from the surfaces of the cooking appliance before
connecting it.
1. Make sure the power switch on the top of the raised
vent is in the up position.
2. Plug the raised vent power plug into the electrical out-
let.
3. Press the power switch once to raise the vent to its
operating position.
4. Once in the up position the vent should begin to draw
air. Turn the variable speed control switch in both direc-
tions to verify that the system is operating correctly.
5. Press the top cap up/down switch once to lower the
vent.
6. Make sure that the top cap on the raised vent intake
does not catch on the back edge of the cooking appli-
ance when the intake is lowered. If interference occurs,
adjust the position of the cooking appliance. Failure
to eliminate any interference may result in permanent
damage to the vent.
If the raised vent is not operational after installation:
• Make sure that power is being supplied to the unit.
• Make sure that power is being supplied to the blower
from the raised vent.
• If the vent will not raise properly or makes a scraping
sound check for obstructions interfering with the raising
of the unit.
If the raised vent still does not function after performing the
above checks, do not attempt to repair it yourself. Contact
Dacor Distinctive Service at (877) 337-3226. Be sure to
have all model and serial numbers from the product data
labels for the raised vent and the blower available when
you call.
Dacor is not responsible for the cost of correcting problems
caused by a faulty installation.
Installation Checklist
Are the anchor legs extended down to make contact
with the floor and tightened into place? Are the anchor
legs fastened to the floor? Is the unit level?
Is the duct work completely installed? Are all joints
attached with sheet metal screws and wrapped with
duct tape?
Are both ends of the remote or in-line blower power
cable connected (to the raised vent and to the blower
itself?)
Are the vent filters installed according to the use and
care manual instructions?
Is the power cord routed away from the hot surfaces of
the cooking appliance.
Is the unit connected to an electrical outlet that meets
the electrical specifications in these instructions?
Has proper operation been verified?
Has the warranty been activated on-line or the warranty
card been filled out completely and mailed?