DISASSEMBLY AND ASSEMBLY
1) Remove the screw which secure the control panel, push up two snap fits and draw forward the control panel assembly.
2) Remove the door open lever from the control panel.
3) Remove four screws which secure the PCB assembly to control panel.
4) Disconnect membrane tail from the connector of the PCB assembly.
5) Detach membrane from the control panel.
6) Remove door open button and button spring from the control panel.
7) Reverse the above steps for reassembly.
6. To remove high voltage capacitor.
1) Remove a screw which secure the grounding ring terminal
of the H.V.diode and the capacitor holder.
2) Remove the H.V. diode from the capacitor holder.
3) Reverse the above steps for reassembly.
High voltage circuit wiring
7. To remove magnetron.
1) Remove a screw which secure the magnetron.
2) Remove the magnetron.
3) Reverse the above steps for reassembly.
NOTE
Never install the magnetron without the metallic gasket plate which is packed with each magnetron to prevent
microwave leakage. Whenever repair work is carried out on magnetron, check the microwave leakage. It shall
not exceed 4mW/cm