Daewoo KOR-631G0P Microwave Oven User Manual


 
PRI NTED CI RCUI T BOARD
1. CIRCUIT CHECK PROCEDURE
1. Low voltage transformer check
The low voltage transformer is located on the P.C.B.
Measuring condition: Input voltage: 220 V / Frequency: 60Hz
2. Voltage Check
- Key check point
- Check method
Terminal Voltage LOAD NO LOAD
4 - 7 AC 12.6 V AC 14.7 V
NO CHECK POINT REMARK
1 IC1 PIN 2,21,30,34 -5VDC
2IC1 PIN 35
T : 16.67ms(60Hz)
3 IC1 PIN 31 OR 32
T : 250 ns(4MHz)
NO MEASURE POINT WAVE FORM REMEDY REMARK
1 MP1 DC -5V±0.25V Replace VL1, EC1 NO LOAD
2 MP2 DC -12V±2.0V Replace EC2, D12,13,14 NO LOAD
NOTE
1. Refer to Circuit Diagram (point 4).
2. Secondary side voltage of the low voltage transformer changes in proportion to fluctuation of power source voltage.
3. The allowable tolerance of the secondary voltage is within 5% of nominal voltage.
NOTE
Each measure point must be measured with GND points.