Daewoo KOR-631G0P Microwave Oven User Manual


 
TROUBLE SHOOTING GUIDE
( TROUBLE 2 )
Display shows all figures selected, but oven does not start cooking, even though desired program and time
are set and start pad is tapped.
CONDITION
CHECK RESULT CAUSE REMEDY
Outlet has
proper voltage
Fuse does not
blow.
Check continuity of
magnetron
No
Continuity
Defective
magnetron
Replace
No
Continuity
Normal
Defective touch
control circuit
Open power
supply cord
Replace
Check continuity of
power supply cord
Adjust
Check continuity of
noise filter board
No
Continuity
Defective line
filter board
Replace
NOTE
All these switches must be replaced at the same time, please refer to “Interlock Mechanism And Adjustment”.
CONDITION
CHECK RESULT CAUSE REMEDY
Turn table
motor and
oven lamp do
not turn on
No
Continuity
Adjust or
replace
Adjust or
replace
Replace
Replace
Malfunction
of primary
interlock
switch
No
Continuity
0 V
Approx.
15 VDC
Check continuity of
primary interlock switch
Check continuity of
secondary interlock and
D.O.M. switches
Check D.C. voltage
being supplied to
RELAY (RY2) coil
Malfunction
of secondary
interlock and
D.O.M. switch
Defective
touch control
circuit
Faulty
contacts of
RELAY
(RY2) or open
relay coil