Before first use of Ice/Water Dispenser
Water mains pressure must not be below 1
bar.
Water mains pressure must not be over 8
bars.
Pumps must be used in case the supply
water pressure drops below 1 bar or if a jug
is going to be used.
The water system of the refrigerator must be
connected to the cold water line. It must not
be connected to the hot water line.
No water may be obtained in the initial start-
up of the refrigerator. This is caused by the
air in the system. To discharge air from the
system, press the Dispenser lever for 1
minute periods until water flows from the
Dispenser. Water flow may be irregular in
the beginning. Irregular water flow will be
normalized after the air in the system is
discharged.
After the initial start-up of the refrigerator
approximately 12 hours must pass before
the water is cold.
Water mains pressure must be between 1-8
bars for the smooth operation of the Ice/
Water Dispenser. To check, see that 1 glass
of water (100 cc) can be filled in 10 seconds.
The first 10 glasses of water should not be
consumed.
Please note, ice cubes will not be ready for
the first 12 hours after switching on the
refrigerator.
If there is not enough ice in the ice
dispenser, ice may not be obtained from the
ice dispenser.
The first 30 cubes of ice to be obtained from
the Ice Dispenser must not be used.
Always use the water filter when a jug is not
being used.
If you want to have the filter change time
calculated automatically and receive a
warning at the end of usage time, please
read "How to have the Filter Usage Time
calculated Automatically" section (page 20).
The water filter must be removed as shown
in the figure when it is going to be replaced
or when it will no longer be used and the
bypass cover must be attached. Please
ensure that Ice Off mode is active before
removing it.
Caution:
The water filter cleans some foreign particles
in the water. It does not purify water from
microorganisms.
Caution:
The Ice Off button must always be pressed
during replacement of the water filter or
installing the by-pass cover.