Delfield 6000 Refrigerator User Manual


 
Vantage 6000™ Series and Glass Door Merchandisers Reach-Ins Service and Installation Manual
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.deleld.com
12
Vantage 6000™ Series and Glass Door Merchandisers Reach-Ins Service and Installation Manual
13
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.deleld.com
STANDARD LABOR GUIDELINES TO REPAIR OR REPLACE PARTS ON DELFIELD EQUIPMENT
Advice and recommendations given by Delfield Service Technicians do not constitute or guarantee any special coverage.
• A maximum of 1-hour is allowed to diagnose a defective component.
• A maximum of 1-hour is allowed for retrieval of parts not in stock.
• A maximum travel distance of 100 miles round trip and 2-hours will be reimbursed.
• Overtime, installation/start-up, normal control adjustments, general maintenance, glass breakage, freight damage, and/or
correcting and end-user installation error will not be reimbursed under warranty unless pre-approved with a Service Work
Authorization from Delfield. You must submit the number with the service claim.
LABOR OF 1-HOUR IS ALLOWED TO REPLACE:
• Thermostat Contactor/Relay
• Infinite Switch Transformer
• Door Jamb Switch Evaporator/Condenser Fan Motor and Blade
• Solenoid Coil Circulating Fan Motor and Blade
• Hi-limit/Thermal Protector Switch Microprocessor Control
• Fan Delay/Defrost Termination Switch Water Level Sensor/Probe
• Compressor Start Components and Overload Protector Door Hinges, Locks, and Gaskets
• Defrost Timer Condensate Element
• Thermometer Springs/Lowerator
• Gear Box
LABOR OF 2 HOURS TO REPLACE:
• Drawer Tracks/Cartridges Defrost Element
• Pressure Control Heating Element
• Solenoid Valve Locate/Repair Leak
LABOR OF 3 HOURS TO REPLACE:
• EPR or CPR Valve Condenser or Evaporator Coil
• Expansion Valve
LABOR OF 4 HOURS TO REPLACE
• Compressor
This includes recovery of refrigerant and leak check.
$35.00 maximum reimbursement for refrigerant recovery (includes recovery machine, pump, torch, oil, flux, minor fittings,
solder, brazing rod, nitrogen, or similar fees.)
REFRIGERANTS
• R22 A maximum of $4.00/lb. or 25¢/oz. will be reimbursed.
• R134A A maximum of $5.00/lb. or 31¢/oz. will be reimbursed.
• R404A A maximum of $12.00/lb. or 75¢/oz. will be reimbursed.