Delfield 6000 Refrigerator User Manual


 
Vantage 6000™ Series and Glass Door Merchandisers Reach-Ins Service and Installation Manual
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.deleld.com
6
Vantage 6000™ Series and Glass Door Merchandisers Reach-Ins Service and Installation Manual
7
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.deleld.com
Programming Example
Defrost Cycle
Time Time
1 2 3 4 1 2 3 4
40 Minute Duration 6 Hour Frequency
Typical Sequence of Operation
Period
Frost Build Time 40 Min
Compressor
Defrost terminated by
Defrost time or temperature
6 Hour Cycle
Next cycle begins
Defrost Timer Programming Guide (all models)
A (2) 4 position dip switch provides user con-
trol of defrost duration and cycle time. The
selection is as follows.
Defrost Time
Dip Switch
Setting min
off off off off void
on off off off 5
off on off off 10
on on off off 15
on on off on 20
on off on off 25
off on on off 30
on on on off 35
off off off on 40
on off off on 45
off on off on 50
on on off on 55
off off on on 60
Cycle Time
Dip Switch
Setting hrs
off off off off void
on off off off 2
off on off off 4
on on off off 6
on on off on 8
on off on off 10
off on on off 12
on on on off 14
off off off on 16
on off off on 18
off on off on 20
on on off on 22
off off on on 24
O
N
O
N
Defrost timer
NOTE: Dip switches shown in default positions.
PURPLE
WHITE
COMPRESSOR
LINE N/O
BROWN
BLACK
BLACK
YELLOW
DEFROST
LINE N/O
N
P1
CYCLE
TIME
DEFROST
TIME
DEFROST
INITIATE
DEFROST ON
INITATE
X
P2
CR
P3
1 2 3 4
O
N
PB
LED
1 2 3 4
O
N