BURNERS AND GRIDS
✓ These parts can be removed and cleaned with appropriate products.
✓ After cleaning, the burners and their flame spreaders must be well dried and correctly
replaced.
✓ It is very important to check that the burner flame spreader and the cap have been cor-
rectly positioned. Failure to do so can cause serious problems.
✓ Check that the electrode “S” (figs. 23 26 and ) is always clean to ensure trouble-free
sparking.
✓ Check that the probe “T” (figs. 23 26 and ) next to each burner is always clean to ensure
correct operation of the safety valves.
✓ Both the probe and ignition plug must be very carefully cleaned.
✓ Note: To avoid damage to the electric ignition do not use it when the burners
are not in place.
F
C
Flame failure
probe "T"
Ignitor "S"
Figure 23