DeLonghi DE302GB Cooktop User Manual


 
GAS SUPPLY:
This appliance is suitable for use with Natural Gas or ULPG. (Check the
“gas type” sticker attached to the appliance).
For Natural Gas the gas supply must be regulated to obtain a pressure of 1 kPa
with t burners operating.
For ULPG models connect the gas supply directly to the appliance test
point adaptor (supplied with the conversion kit) and ensure that the supply pres-
sure is regulated to 2.75 kPa.
Do NOT force the ”elbow“ rotation prior to loosening nut.
Do NOT over tighten the nut at the ”elbow“.
Gas connection for
NATURAL GAS
Figure 9
Figure 8
Gas connection for
ULPG
Gas inlet pipe
Gasket
Brass conical adaptor
(Thread tight: use
suitable seal)
Test point adaptor
Gasket
Brass conical adaptor
(Thread tight: use
suitable seal)
Gas regulator
Gas inlet pipe
9
Test
point
Test
point
1. After connecting the gas supply, check the piping and connections for leaks
using a soap and water solution. The presence of bubbles indicates a leak, tight-
en or replace connections as appropriate.
Warning: Do not use any naked flame to check for leaks.
2. The operation of the appliance MUST be tested before leaving.
3. Adjust the test point pressure or supply pressure to the value which is appropri-
ate for the gas type.
4. Turn on the appliance gas controls and light each burner. Check for a well
defined blue flame without any yellow tipping. If any abnormality is evident then
check that the burner cap is located properly and the injector nipple is aligned
correctly.
heal l