DeLonghi DE302IB Cooktop User Manual


 
19
This cooktop can be built into a working
surface 30 to 40 mm thick and 600 mm
deep.
In order to install the ceramic hob into
the kitchen fixture, a hole with the
dimensions shown in figure 4.1 has to
be made, keeping in consideration the
following:
The cooktop shall not be installed
directly above a dishwasher, fridge,
freezer, washing machine or clothes
dryer, as the humidity may damage
the cooktop electronics.
If the cooktop is installed above an
oven, the oven shall be provided with
cooling fan. The two appliances should
be connected to the electrical supply
with independent connections.
I MP O RT A NT W AR NI N G! T hi s
cooktop requires adequate supply
of fresh, cool air to fully function.
The base of the cooktop must have
direct unrestricted ventilation to the
room where the cooktop is installed.
Follow the requirements of figure 4.3.
The ceramic hob must be kept no less
than 60 mm away from any side wall.
500 mm
650 mm
450 mm
60 mm minimum between the side
of the cut-out and the side wall
Fig. 4.2
7 mm 7 mm
min 30 mm min 30 mm
70 mm
Fig. 4.3
Minimum clearances and
ventilation requirements
(cupboard or drawer space below)
Minimum clearances and
ventilation requirements
(oven installed below)
Oven with
cooling fan
The rear wall must be at least 50 mm from the ceramic hob.
There must be a distance of at least 650 mm between the hob and any wall cupboard
or extractor hood positioned immediately above (see fig. 4.2).
The coatings of the walls of the unit or appliances near the cooktop must be heat
resistant.
Do not install the appliance near inflammable materials (eg. curtains).