23
1
2
NATURAL GAS
REGULATION
LP/PROPANE
REGULATION
A
Fig. 6.5
CONVERSION TO LP/PROPANE GAS
Every oven is provided with a set of injectors for the various types of gas.
Select the injectors to be replaced according to the "INJECTORS TABLE".
The nozzle diameters, expressed in hundredths of a millimetre, are marked on the
body of each injector.
SETTING THE PRESSURE REGULATOR
1. Unscrew the regulator cover;
2. Unscrew the A component, reverse and screw it according to the LP/PROPANE
regulation.
INJECTORS TABLE
NOMINAL
POWER
REDUCED
POWER
LP/PROPANE
11” W.C.P.
NATURAL GAS
4” W.C.P.
BURNERS
BTU/hr BTU/hr
Ø injector
[1/100 mm]
By-pass
[1/100 mm]
Ø injector
[1/100 mm]
By-pass
[1/100 mm]
Oven burner
11000 1500 96 34 164
adjustable
Broil burner
7000 – 78 – 130
–
5. Leak Testing:
IMPORTANT: Leak testing of the appliance shall be conducted as follows:
• After final gas connection is made, turn on manual gas valve and test all
connections in gas supply piping and appliance for gas leaks with a soapy water
solution. During this test all appliance gas valves have to be closed.
• In order to avoid property damage or serious personal injury , never use a Iighted
match. If a leak is present, tighten joint or unscrew, apply more joint compound,
tighten again and retest connection for leak.
ቧ