25
ADJUSTMENT OF THE OVEN BURNER MINIMUM
This needs to be done only for the oven burner (the broil is a fixed capacity) by acting
on the thermostat in the following way:
– Turn on the burner by setting the thermostat knob on position .
– Remove the knob and unscrew the by-pass screw "G" (fig. 7.12) about three times by
passing a small flat screwdriver (Ø 3 mm blade, 100 mm length) through the panel
opening.
– Re-mount the knob and let the oven heat up for about 10 minutes, then bring the knob
to position (minimum) to operate the thermostat by-pass
– After having removed the knob again and being very careful not to turn the tap rod,
slowly screw the by-pass screws “G” (fig. 6.10) until you obtain a flame of 3-4 mm in
height.
N.B. For LP/PROPANE gas the by-pass screw must be fixed thoroughly.
After regulation repeat the operations indicated in paragraph “2. Pressure regulator” at
page 19.
If the oven has been disconnected and then connected again to the gas supply line
repeat the operations indicated in paragraph “5. Leak Testing” at page 23.
IMPORTANT:
After conversion to LP/PROPANE gas has been carried out affix near the data plate, the
conversion label supplied and also affix a conversion label at page 3 of this instruction
manual.
G
Fig. 6.10
ቧ