DeLonghi DEF905E Cooktop User Manual


 
12
CONNECTION OF THE POWER SUPPLY CABLE
Important! This cooker must be connected to the electricity supply only by an au-
thorised person.
To connect the feeder cable to the cooker it is necessary to:
Remove the two screws that hold shield “A” behind the cooker (g. 12).
Open completely the cable clamp “D”.
Fitted with a 6-pole terminal block, position the U bolts onto terminal block ‘B’ (g. 12)
according to the diagrams in gs. 13 - 14.
Feed the supply cable through the cable clamp “D”. The supply cable must be of a
suitable size for the current requirements of the appliance; see the section “Feeder
cable section”.
Connect the phase, neutral and earth wires to terminal “B” according to gures 13 and
14.
Pull the feeder cable and block it with the cable clamp “D”.
Re-mount shield “A”.
N.B. The earth conductor must be left about 3 cm longer than the others.
VOLTAGE AND POWER CONSUMPTION
230/400 V 3N~ 50 Hz 11800 W (51.30 A) (diversity not applied)
240/415 V 3N~ 50 Hz 12800 W (53.33 A) (diversity not applied)
FEEDER CABLE SECTION
This cooker must be connected to electrical supply using V105 insulated cable.
230 V~, 240 V~ 3 x 6 mm
2
(*)
230 V 3~, 240 V~ 4 x 4 mm
2
(*)
400 V 3N~, 415 V 3N~ 5 x 2,5 mm
2
(*)
400 V 2N~, 415 V 2N~ 4 x 4 mm
2
(*)
(*) Connection with wall box connection.
Diversity factor applied.
A diversity factor may be applied to the total loading of the appliance only by a
suitably qualied person.