Dometic RM2191 & RM2193 Refrigerator User Manual


 
3
6. CLEARANCES
Minimum clearances in inches to combustible materials
are:
GG
GG
G: Top 0"
KK
KK
K: Side 0"
LL
LL
L: Bottom 0"
MM
MM
M: Rear 1"
NN
NN
N: See NOTE
P:P:
P:P:
P: See NOTE
NOTENOTE
NOTENOTE
NOTE: Clearance "
MM
MM
M" is between the rearmost part of
the refrigerator and the wall behind the refrigerator.
NOTENOTE
NOTENOTE
NOTE: Clearance "
NN
NN
N" is the distance between the
bottom of the lower vent to the top of upper side vent.
For ventilation height, refer to
Section A. Installation,
Item 5. Ventilation Heights
. See FIG. 2.
Surfaces directly above and sides adjacent to theSurfaces directly above and sides adjacent to the
Surfaces directly above and sides adjacent to theSurfaces directly above and sides adjacent to the
Surfaces directly above and sides adjacent to the
flue outlet must be of, or covered with, fireproofflue outlet must be of, or covered with, fireproof
flue outlet must be of, or covered with, fireproofflue outlet must be of, or covered with, fireproof
flue outlet must be of, or covered with, fireproof
material. See FIG. 2.material. See FIG. 2.
material. See FIG. 2.material. See FIG. 2.
material. See FIG. 2.
NOTENOTE
NOTENOTE
NOTE: Clearance
"P""P"
"P""P"
"P" over top of unit condenser fins
is 1/4 inch. This is the minimum height which can be
allowed over the condenser fins. Whenever possible,
increase this height by up to 11 inches; the more
ventilation you provide, the better the performance you
can expect from the refrigerator.
Minimum Ventilation
Heights In:
5. VENTILATION HEIGHTS
Refer to FIG 1 & FIG. 1A., Pages 2 & 3
Installation with upper sideInstallation with upper side
Installation with upper sideInstallation with upper side
Installation with upper side
vent and lower side ventvent and lower side vent
vent and lower side ventvent and lower side vent
vent and lower side vent
REFRIGERATORREFRIGERATOR
REFRIGERATORREFRIGERATOR
REFRIGERATOR
INCHESINCHES
INCHESINCHES
INCHES
MMMM
MMMM
MM
*Min. Max. *Min. Max.*Min. Max. *Min. Max.
*Min. Max. *Min. Max.*Min. Max. *Min. Max.
*Min. Max. *Min. Max.
RM2191, RM2193 20-5/8 31-5/8 524 803
* This is the minimum height allowable. Where
possible, increase the minimum height by 11
inches (279mm) for a better air flow and cooling
performance.
FIG. 1A
FIG. 2FIG. 2
FIG. 2FIG. 2
FIG. 2